Parts
Department

BOILER PARTS FOR: BoilerSmith,
BURNER PARTS FOR: Beckett,
Carlin, Gordon-Piatt, PowerFlame, Webster, Weishaupt
STOCKED Boiler/Burner Parts including:
Ropes
Tape
Gasket Cloth
Millboard
Blankets
Handhole & Manhole Gaskets & Covers
Oil
Filters
Tigeloop De-Aerator
Electrodes
Igniters
Nozzles
(Delevan, Monarch, Hago & Steinen)
Everlasting
Valve
Liquid
Level Gauge Glass
Motors
Oil
Pumps
Ignition Transformers
Field
Draft Regulators
Guardian
Burner Couplings
Boiler
Tube Brushes
McDonnell & Miller
TC-4 Test-n-Check Valve Pkg.
#21 Make-Up Water Feeder
#47-2 Water Feeder LWCO
#63 Low
Water Cut Off
#63-M Manual Reset LWCO
#64 Low
Water Cut Off
#64-M Manual Reset LWCO
#150 LWCO Pump Control
#150-M Manual Reset
FS4-3 Flow Switch
#42 Pump Control LWCO
PS851-120 Probe Type LWCO
PS851-M-120 Probe Type LWCO, Manual
150-14 150/157 Gasket
37-26 47/47-2 Gasket
#2 and 2-M Switch
#11 Switch
#11M Manual Reset Switch
SA150-106 1 50/157 Bellows
SA47/101/102 47/47-2 Valve & Strainer
Above
Normally Stocked

Boiler
Controls:
Low Water Cut-off - Hotwater and Steam Boilers
Water Feeders - Electric, Mechanical, and Make-up
Valves - Test-n-Check
Flow Switches:
Liquid Flow
Air Flow
Liquid Level Controls:
Conductance Actuated
Pneumatic Actuated
Float Actuated
Flame Safeguard Controls
FIREYE
MacLeod & Grant Ltd. Is a stocking distributor of FIREYE Controls
M-Series II Flame Safeguard Controls
Upgrade your M-Series Controls with M-Series II
¨ M-Series II utilizes existing M-Series Wiring Base
¨
M-Series II components are directly
interchangeable with older M-Series design.
Functions such as relight, two stage
capability, purge timing, and pilot cutoff are determined by the programmer
module. Type of flame scanner (UV, flame rod, or photocell) and Flame Failure
Response Time (FFRT) are determined by the amplifier module. Some programmer
modules have dipswitches for selecting purge timing, pilot trial-for-ignition
(PTFI) timing, and recycle or non-recycle operation. LED indicator lights on
all programmer modules indicate operating status of the control.
|
M-Series |
M-Series II Replacement Modules |
|||
Part #
|
Chassis |
Amplifier |
Programmer |
Programmer Dipswitch
#8 |
|
UVM1D |
MC120 |
MAUV1T |
MP100 |
N/A |
|
UVM1F |
MC120 |
MAUV1 |
MP100 |
N/A |
|
TFM1D |
MC120 |
MART1T |
MP100 |
See Note #1 |
|
TFM1F |
MC120 |
MART1 |
MP100 |
See Note #1 |
|
UVM2 |
MC120 |
MAUV1 |
MP230 |
OFF |
|
TFM2 |
MC120 |
MART1 |
MP230 |
OFF |
|
UVM3 |
MC120 |
MAUV1 |
MP230 |
ON |
|
TFM3 |
MC120 |
MART1 |
MP230 |
ON |
|
UVM3H |
MC120 |
MAUV1 |
MP230H |
ON |
|
TFM3H |
MC120 |
MART1 |
MP230H |
ON |
|
UVM5 |
MC120 |
MAUV1 |
MP560 |
ON |
|
UVM6 |
MC120 |
MAUV1 |
MP560 |
See Note #2 |
|
-
N/A Not
Applicable -
Programmer Dispswitches apply to MP230, MP230H and MP560 Programmers -
Dipswitch #8
sets Recycle/Non-Recycle Operation. (ON = Non-Recycle, OFF = Recycle) -
MP560
Programmer Module has Check Run Switch -
Note 1: For
standing pilot, clip out red jumper on MP100 -
Note 2:
Dipswitch #8 ON when red jumper of UVM6 is clipped. Otherwise, Dipswitch #8
= OFF. |
||||
Call for
current pricing 1-877-750-0500

MacLeod & Grant Ltd. is a
stocking distributor of Honeywell 7800 Series Controls
Honeywell Burner and Boiler Controls
is the leading manufacturer of controls for the burner and boiler controls
industry. We manufacture programming and primary controls, gas valves and
actuators, limit and pressure controls, gas/air pressure switches,
communication equipment plus many more.
Programming
Control
RM7895A1014
RM7896C1010
Primary
Control

RM7890A1015
Keyboard
Display Module
S7800A1001
Amplifier
R7849A1023, Ultraviolet
R7848A1008, Infrared
R7847A1033, Rectification
Purge
Card
ST7800A1039
ST7800A1054
Oil Burner
Control
R8184G4033 30 Second
R8184G4058 15 Second
R8184G4090 15 Second with Alarm Controls
Winters Thermogauges
Manufacturers of Industrial Instrumentation
![]() |
Winters offers a comprehensive line of pressure gauges. Winters pressure gauges are categorized into 3 different series, which includes Premium Series, Quality Series and Economy Series.

ACCESSORIES
Winters offers a full line of related accessories to ensure that your application is properly fitted.
![]() |
Winters offers a wide range of pressure transmitters and transducers. These electronic pressure instruments are available as 4-20mA (milliamp output) or 1-5Vdc (voltage output) utilizing various sensing technologies. Accuracy ranges from .015 to .5%.
![]() |
Winters offers a comprehensive line of pressure switches for various industrial applications. Each series of pressure switches are highly configurable to meet any requirement that you may have.

Winters offers a wide range of direct and remote reading thermometers for various industrial applications. Accuracy ranges from 0.5% to 3% full scale.
Hoffman
Specialty

Valves
Regulators Vents
Steam Traps
Vacuum Breakers
Y-Strainers Pumps





#41 1/8 Steam Air Vent
#71A Steam Air Vent
#75 Steam Main Vent
#77 Water Vent
#40 1/8 Steam Vent
#62 Vacuum Breaker
Bell
& Gossett
Condensate Return Pumps
Condensate Return Units
Bearing Assembly
Series 100 Pump
118 844 Bearing Assembly
Series HV Std. 2
189 165 Bearing Assembly
189 163 Bearing Assembly
189 162 Bearing Assembly
Series Std. 2-1/2, LD3, HD3 Pump
189 105 Bearing
Series PD 35 & 37
186 863 Bearing Assembly


Conbraco Produces both Safety and Safety Relief Valves
For Steam, Air & Gas Applications.
10-Series
Section IV ASME Hot Water Boiler Relief Valves
Brass and bronze ASME Section IV safety relief valves; 15 to 160 psig range,
relieves up to 24,352,000 Btu/hr; brass, satin, or polished chrome finish; for
hot water boilers. Sizes: 1/2" to 2".
These capacity-certified relief valves protect against excessive water pressure
(from thermal expansion) and steam generated when Btu input controls fail.
Valves comply with ASME Section IV requirements. Ideal for
use with boilers, heating systems, and unfired pressure vessels.

13-Series
Low Pressure Steam Heating Boiler
Safety Valves
Bronze, low pressure, ASME Section IV safety relief valves; for small to medium
steam boiler/heating systems; 15 psig top guided; positive drainage of
condensate from seat area; capacity: 407 to 1,900 lbs/hr; three design
configurations. Sizes: 3/4" to 1-1/2".
National Board capacity-certified at 15 psig in accordance with ASME Section
IV; rough or polished chrome finish; positive drainage of condensate from seat
area.
Draft
Controls
Draft
Controls that perform consistently and reliably in a wide
variety of
situations.
From the small,
economical RC
popular in small-flue residential settings, to the sophisticated
M+MG2
the triple-fuel model for flues up to 32.


Type RC oil or coal; residential & commercial
Type M+MG2 solid, oil or gas; commercial
Type MG1 - Gas
MORE BOILER ROOM PARTS
Ψ
EVERLASTING Quick Opening Blowdown Valve
Ψ
KNUCKLE Relief Valves
Ψ
TWIN CITY HOSE Flexible Metal Pump Connectors, Metal Expansion
Joint, Rubber Expansion Joints, Teflon Expansion Joints, Expansion
Compensators.
GENERAL BOILER / BURNER PARTS

Ψ
Oil Stand Pipes for use with fuel transfer pumps
Ψ